LANTUS- insulin glargine injection, solution Amerika Serikat - Inggris - NLM (National Library of Medicine)

lantus- insulin glargine injection, solution

dispensing solutions, inc. - insulin glargine (unii: 2zm8cx04rz) (insulin glargine - unii:2zm8cx04rz) - insulin glargine 100 [iu] in 1 ml - lantus is indicated to improve glycemic control in adults and children with type 1 diabetes mellitus and in adults with type 2 diabetes mellitus. important limitations of use: - lantus is not recommended for the treatment of diabetic ketoacidosis. intravenous short-acting insulin is the preferred treatment for this condition. lantus is contraindicated in patients with hypersensitivity to lantus or one of its excipients. pregnancy category c: subcutaneous reproduction and teratology studies have been performed with insulin glargine and regular human insulin in rats and himalayan rabbits. insulin glargine was given to female rats before mating, during mating, and throughout pregnancy at doses up to 0.36 mg/kg/day, which is approximately 7 times the recommended human subcutaneous starting dose of 10 units/day (0.008 mg/kg/day), based on mg/m2 . in rabbits, doses of 0.072 mg/kg/day, which is approximately 2 times the recommended human subcutaneous starting dose of 10 units/day (0.008 mg/kg/day), based on mg/m2 ,

LANTUS- insulin glargine injection, solution Amerika Serikat - Inggris - NLM (National Library of Medicine)

lantus- insulin glargine injection, solution

tya pharmaceuticals - insulin glargine (unii: 2zm8cx04rz) (insulin glargine - unii:2zm8cx04rz) - insulin glargine 100 [iu] in 1 ml - lantus is indicated to improve glycemic control in adults and pediatric patients with type 1 diabetes mellitus and in adults with type 2 diabetes mellitus. important limitations of use: - lantus is not recommended for the treatment of diabetic ketoacidosis. intravenous short-acting insulin is the preferred treatment for this condition. lantus is contraindicated - in patients with hypersensitivity to lantus or one of its excipients [see ]. warnings and precautions (5.4) pregnancy category c: subcutaneous reproduction and teratology studies have been performed with insulin glargine and regular human insulin in rats and himalayan rabbits. insulin glargine was given to female rats before mating, during mating, and throughout pregnancy at doses up to 0.36 mg/kg/day, which is approximately 7 times the recommended human subcutaneous starting dose of 10 units/day (0.008 mg/kg/day), based on mg/m . in rabbits, doses of 0.072 mg/kg/day, which is approx

HUMALOG MIX75/25- insulin lispro injection, suspension Amerika Serikat - Inggris - NLM (National Library of Medicine)

humalog mix75/25- insulin lispro injection, suspension

physicians total care, inc. - insulin lispro (unii: gfx7qis1ii) (insulin lispro - unii:gfx7qis1ii) - insulin lispro 100 [iu] in 1 ml - humalog mix75/25, a mixture of 75% insulin lispro protamine suspension and 25% insulin lispro injection, (rdna origin), is indicated in the treatment of patients with diabetes mellitus for the control of hyperglycemia. humalog mix75/25 has a more rapid onset of glucose–lowering activity compared with humulin 70/30 while having a similar duration of action. this profile is achieved by combining the rapid onset of humalog with the intermediate action of insulin lispro protamine suspension. humalog mix75/25 is contraindicated during episodes of hypoglycemia and in patients sensitive to insulin lispro or any of the excipients contained in the formulation.

NOVOLOG MIX 70/30- insulin aspart injection, suspension Amerika Serikat - Inggris - NLM (National Library of Medicine)

novolog mix 70/30- insulin aspart injection, suspension

physicians total care, inc. - insulin aspart (unii: d933668qvx) (insulin aspart - unii:d933668qvx) - insulin aspart 100 [iu] in 1 ml - novolog mix 70/30 is an insulin analog indicated to improve glycemic control in patients with diabetes mellitus.   important limitations of use:   in premix insulins, such as novolog mix 70/30, the proportions of rapid acting and long acting insulins are fixed and do not allow for basal versus prandial dose adjustments. novolog mix 70/30 is contraindicated - during episodes of hypoglycemia - in patients with hypersensitivity to novolog  mix 70/30 or one of its excipients. enter section text here pregnancy category b. all pregnancies have a background risk of birth defects, loss, or other adverse outcome regardless of drug exposure. this background risk is increased in pregnancies complicated by hyperglycemia and may be decreased with good metabolic control. it is essential for patients with diabetes or history of gestational diabetes to maintain good metabolic control before conception and throughout pregnancy. insulin requirements may decrease during the first trimester, generally increase during

LEVEMIR- insulin detemir implant Amerika Serikat - Inggris - NLM (National Library of Medicine)

levemir- insulin detemir implant

dispensing solutions, inc. - insulin detemir (unii: 4ft78t86xv) (insulin detemir - unii:4ft78t86xv) - insulin detemir 14.2 mg in 1 ml - levemir is indicated for once- or twice-daily subcutaneous administration for the treatment of adult and pediatric patients with type 1 diabetes mellitus or adult patients with type 2 diabetes mellitus who require basal (long acting) insulin for the control of hyperglycemia. levemir is contraindicated in patients hypersensitive to insulin detemir or one of its excipients.

HUMULIN R- insulin human injection, solution Amerika Serikat - Inggris - NLM (National Library of Medicine)

humulin r- insulin human injection, solution

physicians total care, inc. - insulin human (unii: 1y17cti5sr) (insulin human - unii:1y17cti5sr) - insulin human 100 [iu] in 1 ml - humulin r u-100 is indicated as an adjunct to diet and exercise to improve glycemic control in adults and children with type 1 and type 2 diabetes mellitus. humulin r u-100 may be administered intravenously under proper medical supervision in a clinical setting for glycemic control (see dosage and administration and storage). humulin r u-100 is contraindicated during episodes of hypoglycemia and in patients hypersensitive to humulin r u-100 or any of its excipients. never share needles and syringes. correct syringe type doses of insulin are measured in units . u-100 insulin contains 100 units/ml (1 ml=1 cc). with humulin r, it is important to use a syringe that is marked for u-100 insulin preparations. failure to use the proper syringe can lead to a mistake in dosage, causing serious problems for you, such as a blood glucose level that is too low or too high. syringe use to help avoid contamination and possible infection, follow these instructions exactly. disposable syringes and needles should be used only

NOVOLOG MIX 70/30- insulin aspart injection, suspension Amerika Serikat - Inggris - NLM (National Library of Medicine)

novolog mix 70/30- insulin aspart injection, suspension

novo nordisk - insulin aspart (unii: d933668qvx) (insulin aspart - unii:d933668qvx) - insulin aspart 100 [iu] in 1 ml - novolog mix 70/30 is a mixture of insulin aspart protamine and insulin aspart indicated to improve glycemic control in adult patients with diabetes mellitus. limitations of use: novolog mix 70/30 is contraindicated: risk summary there are no available data with novolog mix 70/30 in pregnant women to inform a drug-associated risk for major birth defects and miscarriage. available information from published randomized controlled trials with insulin aspart use during the second trimester of pregnancy have not reported an association with insulin aspart and major birth defects or adverse maternal or fetal outcomes [see data] . there are risks to the mother and fetus associated with poorly controlled diabetes in pregnancy [see clinical considerations] . in animal reproduction studies, administration of subcutaneous insulin aspart to pregnant rats and rabbits during the period of organogenesis did not cause adverse developmental effects at exposures 8-times and equal to the human subcutaneous dose of 1 unit/kg/day,

NOVOLIN 70/30- human insulin injection, suspension Amerika Serikat - Inggris - NLM (National Library of Medicine)

novolin 70/30- human insulin injection, suspension

novo nordisk - insulin human (unii: 1y17cti5sr) (insulin human - unii:1y17cti5sr) - insulin human 100 [usp'u] in 1 ml - novolin 70/30 is indicated to improve glycemic control in adults and pediatric patients with diabetes mellitus. limitations of use: in novolin 70/30, the proportions of short-acting and intermediate-acting insulins are fixed and do not allow for basal versus prandial dose adjustments. novolin 70/30 is contraindicated: risk summary available data from published studies over decades have not established an association with human insulin use during pregnancy and major birth defects, miscarriage or adverse maternal or fetal outcomes (see data). there are risks to the mother and fetus associated with poorly controlled diabetes in pregnancy (see clinical considerations). animal reproduction studies were not performed. the estimated background risk of major birth defects is 6-10% in women with pre-gestational diabetes with a hba1c >7 and has been reported to be as high as 20-25% in women with a hba1c >10. the estimated background risk of miscarriage for the indicated population is unknown. in the u.s. general

NOVOLIN N- human insulin injection, suspension Amerika Serikat - Inggris - NLM (National Library of Medicine)

novolin n- human insulin injection, suspension

novo nordisk - insulin human (unii: 1y17cti5sr) (insulin human - unii:1y17cti5sr) - insulin human 100 [iu] in 1 ml - novolin n is indicated to improve glycemic control in adults and pediatric patients with diabetes mellitus. novolin n is contraindicated: risk summary available data from published studies over decades have not established an association with human insulin use during pregnancy and major birth defects, miscarriage or adverse maternal or fetal outcomes (see data). there are risks to the mother and fetus associated with poorly controlled diabetes in pregnancy (see clinical considerations). animal reproduction studies were not performed. the estimated background risk of major birth defects is 6-10% in women with pre-gestational diabetes with a hba1c >7 and has been reported to be as high as 20-25% in women with a hba1c >10. the estimated background risk of miscarriage for the indicated population is unknown. in the u.s. general population, the estimated background risk of major birth defects and miscarriage in clinically recognized pregnancies is 2-4% and 15-20%, respectively. clinical considerations diseas

NOVOLOG- insulin aspart injection, solution
INSULIN DILUTING MEDIUM FOR NOVOLOG- water injection injection, solution Amerika Serikat - Inggris - NLM (National Library of Medicine)

novolog- insulin aspart injection, solution insulin diluting medium for novolog- water injection injection, solution

novo nordisk - insulin aspart (unii: d933668qvx) (insulin aspart - unii:d933668qvx) - insulin aspart 100 [iu] in 1 ml - novolog is indicated to improve glycemic control in adults and pediatric patients with diabetes mellitus. novolog is contraindicated: risk summary available information from published randomized controlled trials with insulin aspart use during the second trimester of pregnancy have not reported an association with insulin aspart and major birth defects or adverse maternal or fetal outcomes [see data] . there are risks to the mother and fetus associated with poorly controlled diabetes in pregnancy [see clinical considerations] . in animal reproduction studies, administration of subcutaneous insulin aspart to pregnant rats and rabbits during the period of organogenesis did not cause adverse developmental effects at exposures 8-times and equal to the human subcutaneous dose of 1 unit/kg/day, respectively. pre- and post-implantation losses and visceral/skeletal abnormalities were seen at higher exposures, which are considered secondary to maternal hypoglycemia. these effects were similar to those observed in rats